HT3110S

Technical Specs: 

  • INPUT YES, default frequency=50Hz or settable
  • Cold Start 50%~125%(380VAC/400VAC/415VAC)
  • Acceptable Input Voltage 100% load@80%~125%
  • 90% load@70%~80%
  • 80% load@60%~70%
  • 65% load@50%~60%
  • Single phase in,single phase out
  • Phase line-neutral
  • Transfer Voltage Range   110VAC/115VAC/120VAC
  •     -Line low transfer 116VAC/122VAC/127VAC
  •     -Line low recovery 275VAC/288VAC/300VAC
  •     -Line high transfer 268VAC/279VAC/291VAC
  •     -Line high recovery ≥0.95
  • Input Power Factor 40Hz – 70Hz
  • Input Frequency Range Support Any Generator
  • Generator
  • OUTPUT Settable
  • Frequency adaptable
  • Power 10
  •     -Power(kVA) max 9
  •     -Power(kW) max
  • Output Voltage Pure sine wave
  •     -Waveform 220/230/240VAC
  •     -Nominal voltage ± 1 %
  •     -Voltage regulation ≤5% (50% – 100% -50%)
  •     -Transient response   ≤15ms(0% – 100% -0%)
  •     -Transient recovery ≤1% THD, linear load
  •     -Voltage distortion ≤5% THD, non-linear load
  • Output Frequency settable,±3Hz default
  •     -Synchronization range 0.5~5Hz/s,2Hz/s default
  •     -Slew rate (50±0.05) Hz
  •     -Battery mode
  • Transfer Time 0
  •     -Line mode to battery mode 0
  •     -Inverter to bypass
  • Efficiency 92.0%
  •     -Line mode with battery full charged 98.0%
  •     -ECO mode 91.0%
  •     -Battery mode <48dB@<70%load,70%load;1m away
  • Noise 110%: Transfer to bypass after 10 mins
  • Overload Capability (Line Mode) 130%: Transfer to bypass after 1 min
  • 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)
  • 110%: Shutdown after 10mins (Battery mode)
  • Overload Capability (Battery Mode) 125%:Shutdown after 10s(Battery mode)
  • >125%: Shutdown after 1s (Battery mode)
  • 3:1
  • Crest Ratio
  • BATTERY
  • Rating/Type Depend on the capacity of external batteries
  • Quantity 16
  • DC Voltage 192/240VDC
  • Back-up Time Depend on the capacity of external batteries
  • Battery-Low Voltage (176±3)VDC
  • Charger
  •     -Charging voltage (220±1%)VDC
  •     -Charging current (max) 1A
  •     -Charging time Depend on the capacity of external batteries
  • Leakage current <1mA
  • INDICATOR & ALARM
  • Display LED+LCD
  • Alarm Sounding once per second
  • Fault Continuous beeping
  • INTERFACE
  • Smart RS232 Standard Cable support INVT Power Monitor Software
  • B type USB(optional) Standard Cable support INVT Power Monitor Software
  • EPO Remoted EPO function for customer. Short to activate
  • Dry Contactor(optional) DB9 type and phoenix terminal type for selection. (6 output ports, 1 input port) UPS fault alarm, general alarm, bypass mode, UPS normal mode, battery low voltage alarm, utility failure alarm, remoted shutdown.
  • SNMP(optional) Power Management from SNMP Manager and Web Browser
  • Option SNMP, USB, Dry Contractor(AS400),Parallel Kit, ECO Kit, External Battery Cable(standard model), Maintenance Bypass, Maintenance Bypass Detecting Kit
  • Reserved function Can be designed as different function according to customer’s application